Fagor alarm 9016: Resource out of the permitted range
CNC 8060/8065/8070 CNC error · Fagor 8060/8065/8070
What it means
A PLC program references a resource index beyond the architecture limits. Valid ranges are: I1-I1024, O1-O1024, LI1-LI16, LO1-LO8, M1-M8192, MSG1-MSG1024, ERR1-ERR1024, R1-R1024 with bits B0-B31, plus CLK and TG1-TG4 trigger inputs. These ranges also define the addressing space OEMs use for custom messages and alarms.
Likely causes
- resource index exceeding architecture limit
- program ported from another Fagor family with different limits
- symbolic name resolving to out-of-range number
Triage note: This entry doubles as the reference for OEM/user alarm capacity: up to 1024 distinct ERR texts and MSG texts can be defined per project.
Need the part urgently?