Fagor alarm E003: Power bus voltage drops when torque is demanded
DDS drive display code (AXD/SPD/ACD/SCD seven-segment) · Fagor DDS drives
What it means
With the drive producing torque, the common DC bus collapses, which points to a missing or weak mains phase feeding the power supply or a defective drive module dragging the bus down. The manual instructs checking the condition of the three-phase lines and all drives on the bus, then restarting the system.
Likely causes
- one mains phase missing or a loose L1/L2/L3 terminal at the power supply
- another drive module on the power bus failing internally and loading the bus
- undersized or high-impedance supply line dropping under peak current
- poor bus bar contact between modules