RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / E003

Fagor alarm E003: Power bus voltage drops when torque is demanded

DDS drive display code (AXD/SPD/ACD/SCD seven-segment) · Fagor DDS drives

What it means

With the drive producing torque, the common DC bus collapses, which points to a missing or weak mains phase feeding the power supply or a defective drive module dragging the bus down. The manual instructs checking the condition of the three-phase lines and all drives on the bus, then restarting the system.

Likely causes

  • one mains phase missing or a loose L1/L2/L3 terminal at the power supply
  • another drive module on the power bus failing internally and loading the bus
  • undersized or high-impedance supply line dropping under peak current
  • poor bus bar contact between modules

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • AXD/SPD drive module (rating per machine list)

    drive · Common cause

    Request a quote →
  • XPS/RPS power supply module (rating per machine list)

    power-supply · Check if others ruled out

    Request a quote →

Need the part urgently?

Send us alarm E003 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog