Fagor alarm E100: Internal +5 V out of range

DDS drive display code (AXD/SPD/ACD/SCD seven-segment) · Fagor DDS drives

What it means

One of the drive's internally generated control voltages has left its tolerance band; E100 monitors the +5 V rail while sibling codes cover -5 V (E101), +8 V/-8 V (E102/E103) and +18 V/-18 V (E104/E105). These rails feed the logic and feedback interfaces, so an out-of-range value stops the drive. Persistent trips indicate a failing internal switch-mode supply section on the control boards.

Likely causes

  • aging electrolytic capacitors in the internal auxiliary supply
  • control board defect loading one rail down
  • auxiliary 24 V feed from PS-25B4/APS-24 marginal or overloaded

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • APS-24 auxiliary power supply module (PS-65A systems)

    power-supply · Check if others ruled out

    Request a quote →
  • VeCon board (AXD/SPD/ACD/SCD)

    board · Check if others ruled out

    Request a quote →

Need the part urgently?

Send us alarm E100 with your machine details — typical RFQ turnaround is 24–48h.