RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / E106

Fagor alarm E106: Extreme temperature at the heatsink (IGBTs)

DDS drive display code (AXD/SPD/ACD/SCD seven-segment) · Fagor DDS drives

What it means

IGBT heatsink exceeded its thermal limit; drive cuts PWM to protect the power stage. Warning precursor A.003 appears first.

Likely causes

  • cabinet cooling failed (fan/filter blocked, heat exchanger dead)
  • duty cycle beyond drive rating (S6 abuse, undersized drive)
  • heatsink sensor or its harness drifting

Triage note: Mirrors to CNC as 4003-family alarms (8055: 4005 heatsink overtemp). If error returns within minutes on a cold day with clean filters, the internal NTC/harness is lying - replace module.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • Cabinet fan/filter unit (OEM spec)

    Enclosure cooling - first action · Primary suspect

    Request a quote →
  • AXD 2.75 (upsized if chronic)

    Drive module (next current frame up) · Common cause

    Request a quote →

Need the part urgently?

Send us alarm E106 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog