Fagor alarm E107: Drive overheated (CPU board / enclosure)

DDS drive display code (AXD/SPD/ACD/SCD seven-segment) · Fagor DDS drives

What it means

The temperature inside the drive enclosure measured at the CPU board is too high. Unlike E106 (IGBT heatsink), this reflects ambient/enclosure thermal problems rather than motor duty. Fagor advises lowering the ambient temperature around the module.

Likely causes

  • cabinet cooling failure (blocked filter, dead heat exchanger, failed cabinet fan)
  • drive cooling fan stopped or clogged with dust
  • module mounted too close to heat sources or beyond permitted spacing
  • ambient temperature above specification