Fagor alarm E108: Motor overheated

DDS drive display code (AXD/SPD/ACD/SCD seven-segment) · Fagor DDS drives

What it means

Motor KTY/PTO temperature sensor via the feedback cable reports over-temperature (warning A.002 precedes on FM7 spindles).

Likely causes

  • application demanding repeated current peaks beyond motor thermal rating
  • blocked motor cooling (fan cover felt/lint on self-cooled or forced units)
  • temperature-sensor conductors in the feedback cable damaged (false reading)

Triage note: Measure sensor resistance at the drive connector vs motor datasheet: open/short = cable or sensor; correct value while motor feels hot = genuine overheat, address duty/cooling.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • EEC-SP-x

    Feedback cable carrying temp-sensor pair (rule out first) · Primary suspect

    Request a quote →
  • FXM55.12A / FM7-A037-C-E01 (class-match)

    Motor (after true-overheat confirmed) · Common cause

    Request a quote →