RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / E157

Fagor alarm E157: Too much difference in actual position between the two feedbacks (PP5)

DDS drive display code (AXD/SPD/ACD/SCD seven-segment) · Fagor DDS drives

What it means

Deviation between motor feedback and direct (linear scale) feedback exceeded PP5 ActualPositionMonitoringWindow for >20 ms - the two measurement systems disagree.

Likely causes

  • lost motion between motor and scale: ballscrew backlash, coupling slip, belt jump
  • direct feedback cable/heads marginal (counts dropping on one system only)
  • feedback parameterization wrong (NP133 pitch, ratio NP117) after service

Triage note: Diagnostic gold: command slow full-travel move, log PV188 (motor) vs PV190 (direct) - whichever trace steps backward/flat spots identifies the failing system before any parts are bought. Mirrors CNC alarm 4132.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm E157 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog