Fagor alarm E159: Wrong counting direction during GC3 phase-order test (phases swapped)
DDS drive display code (AXD/SPD/ACD/SCD seven-segment) · Fagor DDS drives
What it means
The drive's GC3 command checks that power phases and feedback phasing agree, and it raised this error because commutation ran against the expected direction. On a spindle this appears after motor or cable replacement, or after someone re-terminated the motor power leads. The error is resettable once wiring is corrected.
Likely causes
- two motor power phases swapped at U/V/W terminal block
- rotor feedback connector re-pinned incorrectly after cable repair
- wrong motor table (.mot) loaded for the connected FM7/FM9 spindle motor
Replacement parts
We supply the following units for this alarm — tested, warranty-backed:
- Request a quote →
MPC spindle motor power cable (Fagor coded cable)
drive · Common cause
Need the part urgently?