Fagor alarm E160: Following error during emergency-stop braking ramp
DDS drive display code (AXD/SPD/ACD/SCD seven-segment) · Fagor DDS drives
What it means
While stopping in an emergency, the actual speed no longer tracks the deceleration ramp bounded by parameters SP71/SP72. Heavy rotating inertia - exactly what a spindle represents - makes this trip if braking demand exceeds what the drive and ballast can absorb. Resettable after adjusting the stop behavior.
Likely causes
- deceleration demand too aggressive for spindle + toolholder inertia
- ballast/regeneration capacity insufficient for repeated fast stops
- SP71/SP72 window set tighter than the mechanical system can follow
- mechanical drag change (bearing preload, brake drag) altering the ramp
Replacement parts
We supply the following units for this alarm — tested, warranty-backed:
- Request a quote →
External ballast resistor sized for spindle inertia
power-supply · Common cause
Need the part urgently?
Send us alarm E160 with your machine details — typical RFQ turnaround is 24–48h.