Fagor alarm E200: Overspeed (actual speed > 112% of SP10 maximum)

DDS drive display code (AXD/SPD/ACD/SCD seven-segment) · Fagor DDS drives

What it means

The rotor feedback reports a speed exceeding the configured maximum SP10 by more than 12%. A free-spinning or back-driven spindle can overshoot easily because of its stored kinetic energy. The manual points first at feedback cabling and velocity-loop tuning (overshoot).

Likely causes

  • motor feedback cable damaged or picking up noise (speed derived from A/B pulses)
  • velocity loop badly tuned, overshooting on command steps
  • spindle run above its designed top speed via wrong gear-stage scaling
  • decoupled/loose encoder wheel giving false pulse rate

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • Spindle motor feedback assembly (1 Vpp sinewave, Fagor motor-mounted)

    encoder · Common cause

    Request a quote →
  • EEC/ENC feedback cable drive-to-motor

    encoder · Primary suspect

    Request a quote →

Need the part urgently?

Send us alarm E200 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog