RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / E201

Fagor alarm E201: Motor overload (motor I2t protection tripped)

DDS drive display code (AXD/SPD/ACD/SCD seven-segment) · Fagor DDS drives

What it means

The thermal model of the spindle motor computed an I²t duty beyond the motor rating. Continuous heavy cutting near the thermal limit, blocked cooling airflow, or a derated (hot) motor will trigger it. Letting the model cool down clears the condition; repeated trips mean the duty cycle or cooling must change.

Likely causes

  • duty cycle beyond motor S1/S6-40% rating (heavy roughing)
  • clogged spindle-motor fan or blocked ventilation in motor bell housing
  • motor thermistor circuit reading high (KTY84/PT100 drift)
  • wrong motor current data after parameter/motor-table edits

Triage note: Compare PV (motor temperature variable) in WinDDSSetup against ambient: a sensor stuck high trips I²t with a cold motor.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm E201 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog