RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / E212

Fagor alarm E212: Overcurrent

DDS drive display code (AXD/SPD/ACD/SCD seven-segment) · Fagor DDS drives

What it means

Excess current through the drive module detected instantaneously; PWM interrupted (category 0 stop). Displayed locally and mirrored to the CNC as error 212 (8055 alarm 4009/4069).

Likely causes

  • phase-phase or phase-ground short in motor cable (coolant at connector typical)
  • motor winding breakdown
  • failed IGBT/driver in the module
  • wrong current-loop parameters causing overshoot trips

Triage note: Reset once. Repeat trip with motor cable removed = replace drive. Trip only under load = megger the motor and cable separately before buying anything.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • MPC-4xS-M

    Motor power cable · Primary suspect

    View part →
  • SPD 1.35 (spindle) / AXD 1.35 (axis), rating-match

    Drive power module · Primary suspect

    Request a quote →
  • FM9-A008-S5C0-E01 (class-match)

    Spindle motor if megger fails · Common cause

    Request a quote →

Need the part urgently?

Send us alarm E212 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog