Fagor alarm E213: Under-voltage at the driver of the IGBT

DDS drive display code (AXD/SPD/ACD/SCD seven-segment) · Fagor DDS drives

What it means

Supply voltage to the IGBT gate-triggering circuits inside the drive fell below the level needed to keep the power switches properly driven. Fagor notes the IGBT driver stage or the IGBT itself may be defective; reset once, and replace hardware if it persists. Continuing to run risks destructive shoot-through of the power stage.

Likely causes

  • IGBT gate-driver supply (bootstrap/driver IC) failure on the power board
  • degraded IGBT module drawing excessive gate current
  • internal ribbon/connector between control and power stages

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • AXD/SPD drive module (power stage replacement usually means module swap)

    drive · Common cause