Home / Alarm Library / Fagor / E214

Fagor alarm E214: Short-circuit at the drive module

DDS drive display code (AXD/SPD/ACD/SCD seven-segment) · Fagor DDS drives

What it means

A short-circuit was detected at the drive output stage, cutting PWM immediately (category 0 stop). After eliminating the cause the error can be reset; if it comes straight back, the manual points to wrong power cable sequence, cables touching each other, bad parameters or a faulty drive.

Likely causes

  • phase-phase or phase-ground short in motor cable (coolant ingress at connectors is typical)
  • motor winding breakdown to frame
  • power cables mis-sequenced or chafed through insulation
  • failed IGBT bridge in the module

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm E214 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog