RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / E253

Fagor alarm E253: I0 not found in two revolutions

DDS drive display code (AXD/SPD/ACD/SCD seven-segment) · Fagor DDS drives

What it means

During homing, the reference mark of the rotary/direct feedback was not seen within two encoder turns.

Likely causes

  • encoder-to-spindle coupling slipping (grub screw backed out)
  • I0 channel conductor broken in feedback cable
  • encoder disk/mark LED degraded
  • homing speed/window parameters (NP166) wrong

Triage note: Scope I0 while bar-turning the shaft by hand: pulse present = parameters; absent = cable then encoder. Always re-torque coupling setscrews with threadlocker after any encoder R&R.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm E253 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog