Fagor alarm E253: I0 not found in two revolutions

DDS drive display code (AXD/SPD/ACD/SCD seven-segment) · Fagor DDS drives

What it means

During homing, the reference mark of the rotary/direct feedback was not seen within two encoder turns.

Likely causes

  • encoder-to-spindle coupling slipping (grub screw backed out)
  • I0 channel conductor broken in feedback cable
  • encoder disk/mark LED degraded
  • homing speed/window parameters (NP166) wrong

Triage note: Scope I0 while bar-turning the shaft by hand: pulse present = parameters; absent = cable then encoder. Always re-torque coupling setscrews with threadlocker after any encoder R&R.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • HA-22132-2500

    Hollow-shaft TTL rotary encoder · Common cause

    View part →
  • HP-1024-C5

    Hollow-shaft 1 Vpp rotary encoder · Common cause

    View part →
  • EC-AS-H / IECD-x

    Encoder extension/feedback cable · Common cause

    Request a quote →

Need the part urgently?

Send us alarm E253 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog