RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / E254

Fagor alarm E254: Distance-coded I0 marks read wrong (direct linear feedback)

DDS drive display code (AXD/SPD/ACD/SCD seven-segment) · Fagor DDS drives

What it means

Drive sampled the distance-coded reference-mark pattern of the linear scale and got inconsistent spacing - semi-absolute homing impossible.

Likely causes

  • oil film/chips on exposed scale window
  • reading gap altered (bracket bumped, cover impact)
  • scale speed outside sampling spec during pass
  • distance-coded head marginal

Triage note: Clean + gap-check resolves most cases; escalate to replacement only if marks remain unreadable at correct gap and speed. Mirrors CNC alarm 4136.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • SV2OX-1140-5-B-A-T

    Distance-coded SV2 scale (vibration-rated) · Common cause

    View part →
  • S2OX-1140-5-A-T

    Distance-coded S2 scale · Common cause

    View part →

Need the part urgently?

Send us alarm E254 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog