Fagor alarm E256: Reference mark not repeatable per revolution of the feedback device

DDS drive display code (AXD/SPD/ACD/SCD seven-segment) · Fagor DDS drives

What it means

The drive compares the index (Z/C/D-derived mark) position at each revolution and found it drifting - pulses are being lost or the measured angle is unstable. For a spindle this directly threatens orientation and rigid tapping repeatability. The error is resettable, but persistence condemns the feedback device.

Likely causes

  • failing rotary spindle encoder (mark amplitude marginal)
  • damaged/intermittent feedback cable or connector pins
  • mechanical slippage of encoder ring/disc on the spindle shaft
  • RP9 tolerance window set unrealistically tight

Triage note: Slightly widening RP9 confirms versus fixes: if the alarm returns at normal settings, replace the encoder.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • Rotary spindle encoder (1024-1250 ppr class w/ Z mark)

    encoder · Primary suspect

    Request a quote →
  • Encoder coupling / mounting wedge check before swap

    encoder · Common cause

    Request a quote →