RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / E300

Fagor alarm E300: Over-temperature at the heatsink of the power supply or compact module

DDS drive display code (seven-segment; PS/XPS/RPS power supplies) · Fagor PS/XPS/RPS

What it means

The power heatsink of the supplying module (PS/XPS/RPS) or of a compact ACD/SCD/CMC drive got too hot and the system stopped to protect it. Let the system rest several minutes and reduce the effort demanded. Older XPS units without numeric display mirror this fault via front-LED combinations.

Likely causes

  • power supply fan failed or clogged
  • sustained cycle above supply rating
  • ambient/cabinet cooling insufficient
  • thermistor drift on heatsink

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • Cooling fan kit for PS/XPS/RPS module

    fan · Common cause

    Request a quote →
  • PS-25B4 / XPS-25 / XPS-65 / RPS-xx module (if power stage cooked)

    power-supply · Check if others ruled out

    Request a quote →

Need the part urgently?

Send us alarm E300 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog