Fagor alarm E302: Short-circuit in the ballast of the power supply module

DDS drive display code (AXD/SPD/ACD/SCD seven-segment) · Fagor DDS drives

What it means

A short was detected across the power supply's ballast branch - the drive latches this and refers you to Fagor service. Wiring damage (nickened insulation to chassis), a failed resistor body or a blown sensing element can present like this. Do not keep resetting into a shorted branch.

Likely causes

  • ballast resistor internal failure (shorted element)
  • chaffed ballast wiring shorted to enclosure
  • ballast control/detection board failure

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • Ballast resistor (PS-25x class) - megger test first

    power-supply · Common cause

    Request a quote →
  • PS power supply module (factory repair/exchange)

    power-supply · Check if others ruled out

    Request a quote →

Need the part urgently?

Send us alarm E302 with your machine details — typical RFQ turnaround is 24–48h.