Fagor alarm E306: Power bus voltage too high (software)
DDS drive display code (seven-segment; PS/XPS/RPS power supplies) · Fagor PS/XPS/RPS
What it means
Software monitoring in the supplying module found the DC bus above its upper threshold — the same condition as E215/E304 but caught by the firmware watchdog. Regenerated energy with nowhere to go is the root cause in nearly all cases. See E304 for the power-supply-side hardware twin of this fault.
Likely causes
- external ballast ER+TH burnt open or its thermostat latched
- ballast selection switches misconfigured on PS-65A
- regen path fault inside XPS/RPS
- steep multi-axis decelerations exceeding dissipation capacity