RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / E314

Fagor alarm E314: Crowbar overload error (I²t of crowbar resistor)

DDS drive display code (seven-segment; PS/XPS/RPS power supplies) · Fagor PS/XPS/RPS

What it means

The I²t protection of the Crowbar resistor opened, meaning the precharge/dissipation resistor absorbed more energy than allowed. This sits alongside soft-start failures (E315/E316) in the charging chain of the DC bus. Check the resistor element and its connections; a cooked crowbar resistor usually smells the part.

Likely causes

  • crowbar/soft-start resistor degraded or open after repeated hard charges
  • shorted bus load forcing long charge currents
  • frequent power cycling of the whole system

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • Crowbar/soft-start resistor (PS/compact-drive internal, model-specific)

    regen-resistor · Common cause

    Request a quote →

Need the part urgently?

Send us alarm E314 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog