Fagor alarm E315: Power supply start-up failure (with E316: compact-drive DC-bus charge timeout)

DDS drive display code (seven-segment; PS/XPS/RPS power supplies) · Fagor PS/XPS/RPS

What it means

Soft-start/pre-charge never completed: bus failed to reach minimum voltage within the watchdog window.

Likely causes

  • ballast/soft-start resistor burnt (PS-25x classic)
  • missing NS1-NS2 jumper on X3 after servicing (E316 maneuver error)
  • internal SoftStart fuse open or crowbar wiring loose
  • supply module control board dead

Triage note: Before condemning the supply: confirm the NS1/NS2 shorting jumper and mains contactor coil actually pull in - a stuck K1 presents identically to a dead module.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm E315 with your machine details — typical RFQ turnaround is 24–48h.