RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / E605

Fagor alarm E605: Feedback alarm: signals A/B of motor feedback too damped

DDS drive display code (AXD/SPD/ACD/SCD seven-segment) · Fagor DDS drives

What it means

The amplitude of the A and/or B incremental channels from the motor feedback fell below acceptance limits (RP1-RP4 windows), meaning the drive no longer trusts position/speed information. The cables, feedback device or X4 motor-feedback board may be defective; four consecutive bad signal cycles trip it (see RV59).

Likely causes

  • motor feedback cable strained, crushed or with water at connectors
  • encoder disk contaminated or LED degradation in rotary feedback
  • resolver excitation/sinewave level out of spec
  • X4 receiver circuit on drive failing
  • RP1-RP4 thresholds set unrealistically tight

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • Motor feedback cable (X4)

    cable · Primary suspect

    Request a quote →
  • SinCoder/TTL feedback built into FM7 spindle motor (replace via motor service)

    encoder · Check if others ruled out

    Request a quote →
  • Resolver (FKM/FXM synchronous motors)

    encoder · Check if others ruled out

    Request a quote →

Need the part urgently?

Send us alarm E605 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog