RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / E607

Fagor alarm E607: Saturation in A and/or B signals of the DIRECT feedback (with E608: signals too low/damped)

DDS drive display code (AXD/SPD/ACD/SCD seven-segment) · Fagor DDS drives

What it means

Same amplitude-window failure as E604 but on the linear-scale input (X3): scale signal clips or fades below usable level.

Likely causes

  • traveling cable fatigue fractures near the drag-chain exit
  • scale head LED aging - amplitude decay (E608 signature)
  • coolant film on the scale window attenuating light
  • RP51-RP54 gains wrong after head replacement

Triage note: E607 (clipping) is often just RP51-54 set too hot after a head swap - recalibrate before replacing. E608 (fade) trends physical: cable, optics, then board. Mirrors CNC alarms 4123/4124.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm E607 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog