Fagor alarm E609: Damaged temperature cable

DDS drive display code (AXD/SPD/ACD/SCD seven-segment) · Fagor DDS drives

What it means

The drive judges the motor temperature-sensor conductors (carried in the feedback cable) to be damaged — open circuit or implausible resistance. Since the same conductors carry KTY/PTO sensor data used for E108-style thermal protection, the drive refuses to run unprotected. Inspect the sensor pair continuity through every connector.

Likely causes

  • broken temperature conductors in flexing section of feedback cable
  • temperature sensor open in motor winding (KTY/PTO failure)
  • connector pins pushed back or corroded
  • aftermarket cable lacking the sensor pairs

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • Motor feedback cable incl. temperature pairs (X4)

    cable · Common cause

    Request a quote →
  • KTY84/PTO winding temperature sensor (motor service part)

    sensor · Check if others ruled out

    Request a quote →