RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / E808

Fagor alarm E808: Encoder not detected (with direct feedback)

DDS drive display code (AXD/SPD/ACD/SCD seven-segment) · Fagor DDS drives

What it means

No direct (second) feedback device responded at connector X3. Confirm the scale/external encoder is connected and undamaged and that GP10 matches the installed direct-feedback type. Sibling codes E809-E812 cover the communication, initialization, defect and mismatch variants on this input.

Likely causes

  • direct feedback cable disconnected or broken
  • linear scale head damaged or read gap lost after impact
  • GP10 set for a different feedback class than installed
  • X3 connector contamination/bent pins

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm E808 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog