RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / E814

Fagor alarm E814: Wrong absolute signals of the FAGOR absolute linear encoder (with E817: CRC check error)

DDS drive display code (AXD/SPD/ACD/SCD seven-segment) · Fagor DDS drives

What it means

Absolute-position telegram from a Fagor absolute scale (LA/SA/GA family) is incoherent or fails CRC - data integrity broken between head and drive.

Likely causes

  • RP64 CRC flag mismatches the connected scale (CRC vs non-CRC model)
  • NP117/NP118 scaling parameters wrong after head swap
  • feedback cable damaged / connector contamination
  • absolute head electronics failing

Triage note: Parameter-first alarm: after ANY head or drive replacement, verify RP64 against the scale's CRC option before ordering hardware. Persistent CRC faults with verified parameters = head or cable.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm E814 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog