RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / E816

Fagor alarm E816: Unstable C and D signals of the motor feedback

DDS drive display code (AXD/SPD/ACD/SCD seven-segment) · Fagor DDS drives

What it means

At drive start-up the CAPMOTOR-X feedback board sees jittering C/D signals - often simply because the spindle was still turning when power was applied. If the machine is guaranteed stationary, the signal chain (encoder, cable, board) is suspect. Not resettable; power-cycle after correcting the cause.

Likely causes

  • spindle coasting/free-spinning during drive initialization
  • failing encoder C/D output stages
  • CAPMOTOR-X feedback board defect
  • broken strands in encoder cable intermittently grounding signals

Triage note: Board-vs-encoder isolation: swap the feedback cable first, then the CAPMOTOR-X board, keeping the encoder last.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm E816 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog