Fagor alarm E818: FAGOR SSI: Error on the absolute track (analog signal < 0.20 Vpp)
DDS drive display code (AXD/SPD/ACD/SCD seven-segment) · Fagor DDS drives
What it means
SSI absolute position cannot be calculated because the incremental track amplitude collapsed below ~0.2 Vpp - counting lost.
Likely causes
- glass scale or steel tape contaminated/scratched
- traverse speed beyond encoder rating skipping tracks
- mounting tolerance (gap/parallelism) violated
- reader head/encoder internally failed
Triage note: Escalation ladder straight from the manual: check speed rating -> verify mounting tolerances -> CLEAN glass/tape -> replace encoder/head. Mirrors CNC alarm 4184.