Fagor alarm E818: FAGOR SSI: Error on the absolute track (analog signal < 0.20 Vpp)

DDS drive display code (AXD/SPD/ACD/SCD seven-segment) · Fagor DDS drives

What it means

SSI absolute position cannot be calculated because the incremental track amplitude collapsed below ~0.2 Vpp - counting lost.

Likely causes

  • glass scale or steel tape contaminated/scratched
  • traverse speed beyond encoder rating skipping tracks
  • mounting tolerance (gap/parallelism) violated
  • reader head/encoder internally failed

Triage note: Escalation ladder straight from the manual: check speed rating -> verify mounting tolerances -> CLEAN glass/tape -> replace encoder/head. Mirrors CNC alarm 4184.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm E818 with your machine details — typical RFQ turnaround is 24–48h.