RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / E821

Fagor alarm E821: FAGOR SSI: Image capturing sensor (CCD) error

DDS drive display code (AXD/SPD/ACD/SCD seven-segment) · Fagor DDS drives

What it means

Self-test of the CCD/LED scanning unit in the absolute encoder or scale head failed.

Likely causes

  • LED illumination degraded below detection threshold
  • CCD damaged by vibration/shock
  • internal moisture corrosion in the head

Triage note: Try cleaning + mounting check first (manual lists them), but a true E821 self-test fail means sealed-head replacement - no field repair. Mirrors CNC alarm 4187.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • LAF10-102-A

    LA-series absolute scale/head (protocol-match) · Primary suspect

    View part →
  • HAF-27-D200-2

    Absolute angular encoder head (rotary) · Common cause

    View part →

Need the part urgently?

Send us alarm E821 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog