RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / E822

Fagor alarm E822: FAGOR SSI: Supply voltage out of range (5.3 V > V > 4.1 V)

DDS drive display code (AXD/SPD/ACD/SCD seven-segment) · Fagor DDS drives

What it means

The 5 V feed reaching the absolute encoder/scale head is out of regulation - head starved or over-volted.

Likely causes

  • encoder power conductors damaged / high-resistance crimp
  • cable length beyond spec causing voltage drop (extension added without recalculation)
  • drive X3/X4 supply regulator drifting

Triage note: Measure 5 V AT THE HEAD connector, not the drive: <4.6 V there with 5.0 V at drive = cable resistance problem; low at both ends = drive supply stage.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • EC-P-D (correct length, no field extensions)

    Feedback power/signal cable · Primary suspect

    Request a quote →
  • XC extension + EC-A-C1 pair (if longer run needed)

    Approved extension cable set · Common cause

    Request a quote →

Need the part urgently?

Send us alarm E822 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog