Fagor alarm E903: RPS: Phase missing in the power line
DDS drive display code (seven-segment; PS/XPS/RPS power supplies) · Fagor PS/XPS/RPS
What it means
Not all three power phases are reaching the RPS module, so it refuses to start regeneration. Verify the power connections are properly made — check upstream fuses, contactor poles and the L1/L2/L3 terminations. Note the FAULT led blinking (not steady) indicates missing phases without any other error being active.
Likely causes
- blown fuse on one phase upstream
- contactor pole welded open or burnt
- loose lug at RPS power terminals
- utility single-phasing event