RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fagor / E904

Fagor alarm E904: RPS: Phase missing in the auxiliary power supply line

DDS drive display code (seven-segment; PS/XPS/RPS power supplies) · Fagor PS/XPS/RPS

What it means

The three phases are not being detected on the dedicated line feeding the RPS integrated auxiliary power supply (which powers control circuits and the 24 V system). Check the connections of that auxiliary tap specifically — the main power phases can be fine while this one is not.

Likely causes

  • fuse protecting the auxiliary transformer tap blown
  • auxiliary line terminations loose
  • auxiliary winding/transformer inside RPS failed

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm E904 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFagor catalog