RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fanuc / - (blink)

Fanuc alarm - (blink)

αi SVM · Fanuc αi SVM

What it means

Inverter: abnormal control power supply - feedback/pulsecoder power path pulling down the SVM control supply.

Likely causes

  • JF* feedback cable shorted or damaged
  • Serial pulsecoder internal short
  • Motor encoder element failure
  • SVM control supply failure

Triage note: Isolation order per 3.2.11: disconnect JF* at SVM (blink stops = cable/pulsecoder side); then disconnect at pulsecoder (blink continues = cable; stops = motor).

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • JF1 feedback cable per motor/axis

    Encoder Feedback Cable · Common cause

    Request a quote →
  • A860-0360-T201

    αi Serial Pulsecoder (catalog item; match motor spec) · Common cause

    View part →
  • A06B-02xx/03xx-Bxxx

    αiS/αiF Servo Motor (built-in encoder) · Check if others ruled out

    Request a quote →
  • A06B-6114-H2xx

    Servo Amplifier Module αiSVM · Check if others ruled out

    Request a quote →

Need the part urgently?

Send us alarm - (blink) with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFanuc catalog