RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fanuc / 01

Fanuc alarm 01

αi PSM · Fanuc αi PSM

What it means

PSM-5.5i to PSM-15i: main-circuit power module (IPM) detected an abnormal condition. PSM-15i to PSM-37i: overcurrent flowed into the input of the main circuit.

Likely causes

  • IPM/IGBT failure in converter input bridge
  • Control supply voltage decrease of the power module (IPM)
  • Input supply voltage imbalance
  • AC reactor specification mismatched to the PSM in use

Triage note: B-65285EN 3.1.1: check supply balance and AC reactor spec BEFORE replacing; if IPM defective replace the PSM. Mirrors as SPM display 30 / SP0030.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • A06B-6087-H115

    Power Supply Module αi PSM (match voltage/rating: H115/H126/H130/H137/H145) · Primary suspect

    Request a quote →
  • A06B-6110/6120/6200/6202-Hxx

    αiPS Power Supply Module (later αi-B/αi-C systems) · Common cause

    Request a quote →
  • IGBT/IPM input bridge per PSM rating

    IGBT Module · Check if others ruled out

    Request a quote →

Need the part urgently?

Send us alarm 01 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFanuc catalog