What it means

Spindle motor overheat - inside temperature of motor exceeds specified level.

Likely causes

  • Spindle motor cooling fan/blower stopped
  • Liquid-cooling system fault (liquid-cooled motors)
  • Ambient temperature out of spec
  • Feedback cable faulty (trip with cold motor)
  • Motor internal thermostat faulty

Triage note: CNC numbers: SP0001 (15i) / 9001 or 7n01 (16i/18i/0i). Trip with a cold motor points to cable/thermostat, not real overheating.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • Spindle motor blower/fan kit per motor model

    Cooling Fan Assembly · Primary suspect

    Request a quote →
  • Spindle motor feedback cable

    Encoder Feedback Cable · Common cause

    Request a quote →
  • αi Spindle Motor A06B-4xxx series per spec

    Spindle Motor · Check if others ruled out

    Request a quote →