What it means

Temperature of the main circuit heat sink has risen abnormally.

Likely causes

  • Main-circuit cooling fan broken
  • Dust accumulation in heat sink / filter
  • Continuous operation above rating (overload)
  • Control printed-circuit board not fully seated (inter-board connector detached)

Triage note: Reseat faceplate/control PCB firmly before condemning the module. Mirrors as SP0058 / 9058.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • Per-module fan kit

    Cooling Fan Assembly · Primary suspect

    Request a quote →
  • A06B-6087-H145

    Power Supply Module αi PSM (if overheating recurs with good cooling) · Common cause

    Request a quote →