Fanuc alarm 03
αi SPM · Fanuc αi SPM
What it means
Fuse on the DC link blown (DC link voltage insufficient).
Likely causes
- SPM internal DC link fuse blown during operation
- Power lead shorted to ground
- Motor winding shorted to ground
- IGBT or IPM module failure in SPM
- DC link wire not connected / loose bus bar
Triage note: B-65285EN: replace the SPM. Megger the motor and leads before powering the replacement or you will blow the second fuse. MCC dropping at estop release also implicates DC link wiring. CNC: SP0003 / 9003.
Replacement parts
We supply the following units for this alarm — tested, warranty-backed:
- Request a quote →
A06B-6111-Hxxx / A06B-6112-Hxxx
Spindle Amplifier Module αiSP (rating-dependent) · Primary suspect
- Request a quote →
αi Spindle Motor per spec
Spindle Motor · Common cause
- Request a quote →
Spindle motor power lead set
Motor Power Cable · Common cause