What it means

Fuse on the DC link blown (DC link voltage insufficient).

Likely causes

  • SPM internal DC link fuse blown during operation
  • Power lead shorted to ground
  • Motor winding shorted to ground
  • IGBT or IPM module failure in SPM
  • DC link wire not connected / loose bus bar

Triage note: B-65285EN: replace the SPM. Megger the motor and leads before powering the replacement or you will blow the second fuse. MCC dropping at estop release also implicates DC link wiring. CNC: SP0003 / 9003.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 03 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFanuc catalog