RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fanuc / 04

Fanuc alarm 04

αi PSM · Fanuc αi PSM

What it means

In the main circuit the DC voltage (DC link) has dropped.

Likely causes

  • Small power dip / brown-out
  • Low input supply voltage
  • Main circuit switched off with emergency stop released (sequence fault)
  • Loose DC link bus bar between PSM and SVM/SPM

Triage note: Check incoming 3-phase supply and MCC sequence first; rarely a failed PSM. If several modules show low DC link simultaneously the root cause is upstream. Mirrors as SP0051 / 9051.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • A06B-6087-H126

    Power Supply Module αi PSM (only after supply/sequence checks pass) · Check if others ruled out

    View part →

Need the part urgently?

Send us alarm 04 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFanuc catalog