αi PSM · Fanuc αi PSM

What it means

Main circuit capacitor was not recharged within the specified time (precharge failure).

Likely causes

  • Too many SVM/SPM modules connected to one PSM (over-spec loading)
  • DC link short-circuit downstream
  • Recharge current-limiting resistor defective (on distributing board)

Triage note: Measure DC link for shorts and count connected axes against PSM spec before replacing hardware. Mirrors as SP0033 / 9033.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • Distributing/precharge board per PSM model

    Amplifier Control Board · Common cause

    Request a quote →
  • A06B-6120-H045

    αiPS Power Supply Module (upgrade capacity or replace failed unit) · Common cause

    Request a quote →

Need the part urgently?

Send us alarm 05 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFanuc catalog