RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fanuc / 07

Fanuc alarm 07

αi PSM · Fanuc αi PSM

What it means

DC voltage at the DC link is abnormally high.

Likely causes

  • Excessive regenerated power - PSM discharge capacity insufficient for connected axes
  • AC power source output impedance too high (over 7% variation at max output)
  • Main circuit switched off with emergency stop released (sequence fault)

Triage note: Mirrors as SP0011 / 9011 on the SPM. Common after adding axes or increasing acceleration.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • A06B-6110/6120-Hxx next capacity step up

    αiPS Power Supply Module (undersized for application) · Common cause

    Request a quote →
  • A06B-6087-H145

    Power Supply Module αi PSM (failed regen discharge stage) · Check if others ruled out

    Request a quote →

Need the part urgently?

Send us alarm 07 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFanuc catalog