Home / Alarm Library / Fanuc / 08

Fanuc alarm 08

αi PSMR · Fanuc αi PSM

What it means

Excessive short-term regenerative power detected.

Likely causes

  • Insufficient regenerative resistance for duty cycle
  • Regenerative discharge circuit failure inside PSMR
  • External regen resistor open or mis-wired

Triage note: B-65285EN: regenerative circuit abnormal - replace the PSMR. Check resistor value within +/-20% first.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • A06B-6077-H111

    Power Supply Module α PSMR (resistive-regen type) · Common cause

    Request a quote →
  • External regenerative resistor unit per machine spec

    Regenerative Resistor Unit · Primary suspect

    Request a quote →