RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fanuc / 09

Fanuc alarm 09

αi SPM · Fanuc αi SPM

What it means

Main circuit overload / IPM overheat - heat sink of SPM overtemperature. Issued on SPM-15i and larger; SPM-2.2i to 11i report alarm 12 for the same condition.

Likely causes

  • SPM cooling fan stopped (check CX1A/B fan feed)
  • Heat sink caked with dust/coolant mist
  • Load above continuous rating
  • Control PCB not fully seated
  • SPM faulty (trips with cold, lightly loaded sink)

Triage note: CNC: SP0009 / 9009. Dirty heatsinks from coolant mist are the classic root cause; blow out before condemning hardware.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 09 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFanuc catalog