RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fanuc / 1

Fanuc alarm 1

αi SVM · Fanuc αi SVM

What it means

Inverter: internal cooling fan stopped.

Likely causes

  • Fan seized / foreign material in fan
  • Faceplate (control PCB) not pushed fully home
  • Fan connector not attached correctly
  • SVM internal fan-drive failure

Triage note: CNC-side companion alarms SV0444. Replace fan first; SVM only if alarm returns.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • Per-module fan kit (order by SVM model)

    Cooling Fan Assembly · Primary suspect

    Request a quote →
  • A06B-6114-H2xx

    Servo Amplifier Module αiSVM (rating-dependent, e.g. H202/H208/H212) · Common cause

    Request a quote →

Need the part urgently?

Send us alarm 1 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFanuc catalog