αi SPM · Fanuc αi SPM

What it means

DC link overcurrent / IPM alarm - excessively large current flowed into the DC link of the main circuit; on SPM-2.2i to 11i indicates main-circuit IPM detected overcurrent/overload.

Likely causes

  • SPM power element (IGBT/IPM) destroyed
  • Motor power lead short / ground fault
  • Motor winding insulation failure
  • Dirty heat sink causing thermal death of power elements
  • Speed sensor signal error
  • Incorrect motor-specific parameters

Triage note: THE most-searched Fanuc spindle failure (AL-12 field guides everywhere; CNC numbers SP0012 / 9012 / SP9012). Hard failure that will not reset = dead transistor module, replace SPM. Intermittent = motor/cable insulation - megger before fitting the new SPM.