Fanuc alarm 14: Amplifier ID data inconsistent with software series/edition

αi SPM · Fanuc αi SPM

What it means

The αi SPM detected that its ID data does not match the series and edition of the spindle control software. This appears at power-up and points to an amplifier whose hardware identity is incompatible with the loaded software.

Likely causes

  • SPM replaced with unit of wrong specification/series
  • Corrupt ID data in amplifier control board
  • Wrong spindle software series for installed amplifier

Triage note: Older documents label this simply as a ROM alarm.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • A06B-6111-Hxxx / A06B-6112-Hxxx (correct-series SPM)

    amplifier · Primary suspect

    Request a quote →