Fanuc alarm 15: Spindle/output switching sequence error
αi SPM · Fanuc αi SPM
What it means
In output-switching or spindle-switching control, the switching operation sequence was not completed correctly — the power-lead state check signal did not transition within one second of the switch request. Machine-side sequence problem rather than drive electronics in most cases.
Likely causes
- Faulty magnetic contactor / switch unit for power-lead switching
- I/O unit or contact-check wiring defective
- Ladder sequence takes longer than 1 s to switch
Replacement parts
We supply the following units for this alarm — tested, warranty-backed:
- Request a quote →
Magnetic contactor / spindle switch unit
amplifier · Common cause
Need the part urgently?
Send us alarm 15 with your machine details — typical RFQ turnaround is 24–48h.