RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fanuc / 195

Fanuc alarm 195: I/O LINK ALARM

30i/31i/32i system alarm · Fanuc 30i/31i/32i-B

What it means

A communication error occurred on the FANUC I/O Link (JD1A/JD1B daisy chain) connecting the PMC to operator panels and I/O units. The detailed code shown alongside points at the slave station concerned. Typical triggers are an instantaneous power dip on a slave device, bad or poorly seated I/O Link cable, noise pickup, or a failed I/O unit.

Likely causes

  • Instantaneous power failure or unstable voltage at an I/O Link slave
  • Faulty wiring or incomplete contact of the I/O Link cable (JD1A/JD1B)
  • Electrical noise on the I/O Link run
  • Failed I/O unit or operator panel interface

Triage note: System alarm 194 reports the equivalent fault on I/O Link i.

Need the part urgently?

Send us alarm 195 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFanuc catalog