Fanuc alarm 29

αi SPM · Fanuc αi SPM

What it means

Short-period overload - excessive load (standard: load meter 9V) applied continuously beyond set period (default 30 s).

Likely causes

  • Genuine cutting overload
  • Spindle mechanically locked (brake/sequence)
  • Wrong motor power lead phase sequence
  • Feedback cable A/B signals wrong or broken
  • Spindle sensor failure; SPM failure if spindle will not turn at all

Triage note: CNC: SP0029 / 9029. Check load meter and manual-rotation speed indication before replacing electronics.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • Spindle sensor + feedback cable

    Spindle Sensor Kit · Common cause

    Request a quote →
  • Spindle motor feedback cable

    Encoder Feedback Cable · Common cause

    Request a quote →
  • A06B-6111-Hxxx

    Spindle Amplifier Module αiSP (if spindle will not rotate at all) · Check if others ruled out