Fanuc alarm 30: Overcurrent in converter input circuit (PSM alarm mirrored)

αi SPM · Fanuc αi SPM

What it means

Displayed on the αi SPM this code means overcurrent flowed into the input of the main circuit of the common power supply (IPM detection on smaller PSMs). Check the PSM status display for the primary code.

Likely causes

  • Input supply voltage imbalance
  • AC reactor specification mismatched to PSM
  • IGBT/IPM failure in the PSM input bridge

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 30 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFanuc catalog